This paper presents the results of the measured ventilation flow rates through a roof-mounted inflow/outflow natural ventilator and of the wind pressures measured on the terminal under real conditions. The experiments were conducted at full scale at the former Silsoe Research Institute wind engineering test site using a 6 m cubic test building, referred to as the Silsoe cube, and using a test house. Ventilation rates and free-stream wind speed were measured using ultrasonic anemometers. The nominally 800 mm × 800 mm ventilation terminal on the Silsoe cube achieved a peak ventilation rate of 0·06 m3/s per m/s wind speed although the data also indicated periods when the ventilation rate dropped to approximately zero for a specific wind direction due to the vent then being in the position of flow re-attachment following separation at the windward leading edge of the roof. This has led to better knowledge in relation to the siting of such terminals. A similar terminal monitored on the test house achieved a peak ventilation rate of nearly 0·1 m3/s per m/s wind speed. The ventilation unit proved to be an effective means of providing natural ventilation and is likely to broaden the application of natural ventilation. The results of pressure measurements on the terminal louvres and the internal pressure in the cube, coupled with the measurements of the corresponding ventilating flow rate mechanisms, provide unique data with which to establish procedures for the rational design of such terminals, which is also outlined in the paper.
Article navigation
April 2010
Research Article|
April 01 2010
Measurements of the performance of a wind-driven ventilation terminal Available to Purchase
A. D. Shea, MPhil EngD DMS CEng MCIBSE;
A. D. Shea, MPhil EngD DMS CEng MCIBSE
Department of Architecture and Civil Engineering
University of Bath, UK
Search for other works by this author on:
A. P. Robertson, PhD CEng CEnv MIStructE MIAgrE;
A. P. Robertson, PhD CEng CEnv MIStructE MIAgrE
School of Civil Engineering
University of Birmingham, UK and Building Product Design Ltd, Hadlow, Kent, UK
Search for other works by this author on:
G. J. Levermore, PhD DIC ARCS DMS CEng MInstE MASHRAE FCIBSE;
G. J. Levermore, PhD DIC ARCS DMS CEng MInstE MASHRAE FCIBSE
School of Mechanical
Aerospace and Civil Engineering, The University of Manchester, UK
Search for other works by this author on:
N. M. Rideout, BA(Hons)
N. M. Rideout, BA(Hons)
Building Product Design Ltd
Hadlow, Kent, UK
Search for other works by this author on:
Publisher: Emerald Publishing
Revision Received:
January 13 2009
Accepted:
November 17 2009
Online ISSN: 1751-7702
Print ISSN: 0965-0911
© 2010 Thomas Telford Ltd
2010
Proceedings of the Institution of Civil Engineers - Structures and Buildings (2010) 163 (2): 129–136.
Article history
Revision Received:
January 13 2009
Accepted:
November 17 2009
Citation
Shea AD, Robertson AP, Levermore GJ, Rideout NM (2010), "Measurements of the performance of a wind-driven ventilation terminal". Proceedings of the Institution of Civil Engineers - Structures and Buildings, Vol. 163 No. 2 pp. 129–136, doi: https://doi.org/10.1680/stbu.2010.163.2.129
Download citation file:
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.
