Modular construction is widely used for residential buildings of four to eight storeys and there is pressure to extend this relatively new form of construction to 12 storeys or more. This paper reviews recent modular technologies, and also presents load tests and the analysis of light steel modular walls in compression. A design method for high-rise modular applications is presented taking account of second-order effects and installation tolerances. For the modular walls tested, it was found that the plasterboard and external sheathing boards effectively prevent minor axis buckling of the C sections, so that failure occurred either by major axis buckling or local crushing of the section. In all cases, the results of the tests on 75 mm and 100 mm deep × 1·6 mm thick C sections exceeded the design resistance to BS 5950-5 by 10 to 40%. However, an eccentricity of 20 mm in load application reduced the failure load by 18 to 36% owing to local crushing of the C section. Tension tests on typical connections between the modules and corridors gave a failure load of 40 kN, which is adequate to transfer wind forces to a braced core and also to provide tying action in the event of loss of support to one corner of a module. Corner posts provide enhanced compression resistance but their buckling resistance is dependent on the sway stiffness of the wall panel. It is also shown that the notional horizontal force approach for steel structures presented in BS 5950-1 should be increased for modular construction.
Article navigation
June 2010
Research Article|
June 01 2010
Modular design for high-rise buildings
R. M. Lawson, BSc (Eng), PhD, CEng, MICE, MIStructE, MASCE, ACGI;
R. M. Lawson, BSc (Eng), PhD, CEng, MICE, MIStructE, MASCE, ACGI
SCI Professor of Construction Systems
University of Surrey, Guildford, UK
Search for other works by this author on:
J. Richards, BSc, CEng, MICE
J. Richards, BSc, CEng, MICE
Technical Director
WSP Cantor Seinuk, London, UK
Search for other works by this author on:
Publisher: Emerald Publishing
Revision Received:
January 24 2008
Accepted:
September 07 2009
Online ISSN: 1751-7702
Print ISSN: 0965-0911
© 2010 Thomas Telford Ltd
2010
Proceedings of the Institution of Civil Engineers - Structures and Buildings (2010) 163 (3): 151–164.
Article history
Revision Received:
January 24 2008
Accepted:
September 07 2009
Citation
Lawson RM, Richards J (2010), "Modular design for high-rise buildings". Proceedings of the Institution of Civil Engineers - Structures and Buildings, Vol. 163 No. 3 pp. 151–164, doi: https://doi.org/10.1680/stbu.2010.163.3.151
Download citation file:
New and popular articles
Suggested Reading
Numerical study on seismic behaviour of buckling-restrained steel plate shear walls
Proceedings of the Institution of Civil Engineers - Structures and Buildings (October,2020)
When should shear-flexible stability functions be used in elastic structural analysis?
Proceedings of the Institution of Civil Engineers - Structures and Buildings (February,2002)
Finding displacements from measured strains in 2D frames
Proceedings of the Institution of Civil Engineers - Engineering and Computational Mechanics (December,2008)
Esplanade metro station in Kolkata, India: from concept to optimisation
Proceedings of the Institution of Civil Engineers - Civil Engineering (May,2021)
Steel sway frames tested to collapse
Proceedings of the Institution of Civil Engineers - Structures and Buildings (August,2003)
Related Chapters
Tunnelling
The Essence of Geotechnical Engineering: 60 years of Géotechnique
Analysis of progressive failure and cracking in old British dams
Selected papers on geotechnical engineering by P R Vaughan
Finite element analysis of progressive failure of Carsington embankment
Selected papers on geotechnical engineering by P R Vaughan
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.