Concrete structures suffer from corrosion if chloride ions in the environment penetrate to the depth of reinforcing steel; surfaces periodically wetted with chloride solution are at most risk, when chloride ions can enter concrete by combined diffusion and absorption. BS8500-1 recommended minimum cover requirements primarily assume that chloride ingress is diffusion controlled, and absorption is only partly accounted for, so cover values may be inadequate. This paper investigates factors that influence absorption of chloride ions into concrete and how this affects distribution of chloride at different depths from the surface. Concrete cubes (CEM I cement; water/cement ratio 0·45) are subjected to repeated wetting (with 50% saturated salt solution) and drying cycles, during which their mass is monitored. The effective porosity, weight and distance sorptivity and chloride penetration depths are calculated for a number of curing, conditioning and drying conditions. Samples are extracted from the cubes at a range of depths and analysed for chloride content. Results show that the quantity of chloride entering the concrete, and in particular surface chloride content, is very sensitive to effective porosity/drying conditions immediately before wetting; also as much as 31% of the protection provided by concrete cover can be lost after exposure to just one wet/dry cycle, thereby significantly reducing time to corrosion of concrete structures.
Article navigation
February 2014
Research Article|
February 01 2014
Chloride penetration in concrete subject to wet/dry cycling: influence of moisture content Available to Purchase
Chanakya Arya, PhD, DIC, CEng, MICE;
Chanakya Arya, PhD, DIC, CEng, MICE
Senior Lecturer
University College London, London, UK
Search for other works by this author on:
Samira Bioubakhsh, PhD;
Samira Bioubakhsh, PhD
Research Student
University College London, London, UK
Search for other works by this author on:
Perry Vassie, PhD, MMath
Perry Vassie, PhD, MMath
Visiting Professor
University College London, London, UK
Search for other works by this author on:
Publisher: Emerald Publishing
Revision Received:
April 24 2012
Accepted:
January 04 2013
Online ISSN: 1751-7702
Print ISSN: 0965-0911
ICE Publishing: All rights reserved
2014
Proceedings of the Institution of Civil Engineers - Structures and Buildings (2014) 167 (2): 94–107.
Article history
Revision Received:
April 24 2012
Accepted:
January 04 2013
Citation
Arya C, Bioubakhsh S, Vassie P (2014), "Chloride penetration in concrete subject to wet/dry cycling: influence of moisture content". Proceedings of the Institution of Civil Engineers - Structures and Buildings, Vol. 167 No. 2 pp. 94–107, doi: https://doi.org/10.1680/stbu.12.00027
Download citation file:
Suggested Reading
Hybrid anode concrete corrosion protection – independent study
Proceedings of the Institution of Civil Engineers - Construction Materials (November,2016)
Control of reinforcement corrosion by surface treatment of concrete
Proceedings of the Institution of Civil Engineers - Structures and Buildings (February,2000)
Cathodic protection on the UK's Midland Links motorway viaducts
Proceedings of the Institution of Civil Engineers - Bridge Engineering (August,2013)
Service life extension of SH16 bridges – New Zealand's first hybrid corrosion protection
Proceedings of the Institution of Civil Engineers - Bridge Engineering (August,2019)
Best practice in the management and protection of concrete assets
Proceedings of the Institution of Civil Engineers - Forensic Engineering (May,2021)
Related Chapters
CRITERIA FOR AND PREDICTION OF LIMIT STATES OF DEGRADATION OF REINFORCED CONCRETE STRUCTURES
Role of Concrete in Nuclear Facilities
ASSESSMENT OF CORROSION DAMAGED REINFORCED CONCRETE STRUCTURES
Role of Concrete in Nuclear Facilities
A galvanic sensor for monitoring corrosion of steel in carbonated concrete
ICE Themes Smart Concrete
Recommended for you