The objective of the work is to investigate the effect on the distribution of chloride at different depths of some factors concerning concrete pore structure, namely water/cementitious material ratio, cement type and percentage ground granulated blast furnace slag (GGBS). Concrete cubes are subjected to repeated wetting and drying cycles with various concentrations of sodium chloride solution, during which their mass is monitored. The effective porosity, weight and distance sorptivity and chloride solution penetration depths are calculated. Samples are extracted from the cubes at a range of depths and analysed for chloride content. The results show that the most significant effect of sorptivity on long-term chloride ingress to concrete is its effect on surface chloride content. The value of this parameter is a way of taking account of absorption when modelling chloride ingress under cyclic wetting and drying conditions. The values of cover depth recommended in BS8500-1 that are needed to ensure a time to corrosion of 100 year are calculated assuming the surface chloride content is 0·14% for GGBS and pulverised fuel ash (PFA) concretes. Our cyclic wetting and drying experiments produce higher surface chloride contents (0·29–0·62%) that would lower the time to corrosion using the cover depths recommended in the code.
Article navigation
June 2014
Research Article|
June 01 2014
Chloride penetration in concrete subject to wet–dry cycling: influence of pore structure
Chanakya Arya, BSc, PhD, DIC, CEng, MICE;
Chanakya Arya, BSc, PhD, DIC, CEng, MICE
Senior Lecturer
University College London, London, UK
Search for other works by this author on:
Perry Vassie, BSc, PhD, MMath;
Perry Vassie, BSc, PhD, MMath
Visiting Professor
University College London, London, UK
Search for other works by this author on:
Samira Bioubakhsh, BSc, PhD
Samira Bioubakhsh, BSc, PhD
Research student
University College London, London, UK
Search for other works by this author on:
Publisher: Emerald Publishing
Revision Received:
September 06 2012
Accepted:
June 04 2013
Online ISSN: 1751-7702
Print ISSN: 0965-0911
ICE Publishing: All rights reserved
2014
Proceedings of the Institution of Civil Engineers - Structures and Buildings (2014) 167 (6): 343–354.
Article history
Revision Received:
September 06 2012
Accepted:
June 04 2013
Citation
Arya C, Vassie P, Bioubakhsh S (2014), "Chloride penetration in concrete subject to wet–dry cycling: influence of pore structure". Proceedings of the Institution of Civil Engineers - Structures and Buildings, Vol. 167 No. 6 pp. 343–354, doi: https://doi.org/10.1680/stbu.12.00067
Download citation file:
Suggested Reading
Hybrid anode concrete corrosion protection – independent study
Proceedings of the Institution of Civil Engineers - Construction Materials (November,2016)
Control of reinforcement corrosion by surface treatment of concrete
Proceedings of the Institution of Civil Engineers - Structures and Buildings (February,2000)
Cathodic protection on the UK's Midland Links motorway viaducts
Proceedings of the Institution of Civil Engineers - Bridge Engineering (August,2013)
Service life extension of SH16 bridges – New Zealand's first hybrid corrosion protection
Proceedings of the Institution of Civil Engineers - Bridge Engineering (August,2019)
Best practice in the management and protection of concrete assets
Proceedings of the Institution of Civil Engineers - Forensic Engineering (May,2021)
Related Chapters
CRITERIA FOR AND PREDICTION OF LIMIT STATES OF DEGRADATION OF REINFORCED CONCRETE STRUCTURES
Role of Concrete in Nuclear Facilities
ASSESSMENT OF CORROSION DAMAGED REINFORCED CONCRETE STRUCTURES
Role of Concrete in Nuclear Facilities
A galvanic sensor for monitoring corrosion of steel in carbonated concrete
ICE Themes Smart Concrete
Recommended for you