Double-headed studs are used as punching shear reinforcement in reinforced or prestressed slabs and footings. Owing to an improved anchoring behaviour, double-headed studs have a higher load capacity than stirrups. Double-headed studs are quick to install and are therefore more cost-effective than stirrups. Previously in Europe, national technical approvals specified the design of double-headed studs. Since the end of 2012, European technical approvals have been available. All approvals are based on the same design method, which is used in combination with BS EN 1992-1-1. It is necessary to distinguish between punching shear failure in slabs and foundations with and without shear reinforcement. In slabs and foundations with shear reinforcement, a failure can occur at maximum load level, in and outside the shear-reinforced zone. The European technical approvals provide design equations for all types of failure modes. To quantify the safety level of the design provisions for slabs, footings, and ground slabs with and without shear reinforcement, test evaluations based on a reliable data bank are shown. The paper also provides useful background information and additional design recommendations for applications, which are not covered by the design provisions of the European technical approvals.
Article navigation
August 2014
Research Article|
August 01 2014
European punching design provisions for double-headed studs
Marcus Ricker, MSc, Dr-Ing;
Marcus Ricker, MSc, Dr-Ing
Product Development Engineer
Research Development Engineering, Halfen GmbH, Langenfeld, Germany
Search for other works by this author on:
Frank Häusler, Dr-Ing
Frank Häusler, Dr-Ing
Team Manager
Research Development Engineering, Halfen GmbH, Langenfeld, Germany
Search for other works by this author on:
Publisher: Emerald Publishing
Revision Received:
June 28 2013
Accepted:
September 23 2013
Online ISSN: 1751-7702
Print ISSN: 0965-0911
ICE Publishing: All rights reserved
2014
Proceedings of the Institution of Civil Engineers - Structures and Buildings (2014) 167 (8): 495–506.
Article history
Revision Received:
June 28 2013
Accepted:
September 23 2013
Citation
Ricker M, Häusler F (2014), "European punching design provisions for double-headed studs". Proceedings of the Institution of Civil Engineers - Structures and Buildings, Vol. 167 No. 8 pp. 495–506, doi: https://doi.org/10.1680/stbu.13.00047
Download citation file:
New and popular articles
Suggested Reading
Modelling ground vibrations induced by harmonic loads
Proceedings of the Institution of Civil Engineers - Geotechnical Engineering (April,2016)
Settlement prevision of piles under vertical load
Proceedings of the Institution of Civil Engineers - Geotechnical Engineering (October,2003)
Lateral behaviour of composite tapered piles in dense sand
Proceedings of the Institution of Civil Engineers - Geotechnical Engineering (July,2005)
Rock-socketed pile design and construction: a better way?
Proceedings of the Institution of Civil Engineers - Geotechnical Engineering (July,2006)
The Europa International Foundation Directory 2011 (20th edition)
Reference Reviews (January,2012)
Related Chapters
Tower crane bases
Temporary Works: Principles of Design and Construction
Foundation types and conceptual design principles
ICE Manual of Geotechnical Engineering, Volume II: Geotechnical design, construction and verification
Slope stabilisation methods
ICE Manual of Geotechnical Engineering, Volume II: Geotechnical design, construction and verification
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.