Conventional concrete-filled-tube columns may have welding defects when welders of limited skill have been involved in their production; such defects could cause a rapid degradation of the columns’ strength during a fire. In the study reported in this paper, non-welded columns with mechanical strip connections were developed. Their structural performance, plus that of a typical welded column, was evaluated under both ambient and elevated temperatures. Axial loads were applied to all specimens; for fire resistance the axial load ratio was 40% and an ISO 834 standard fire curve was applied without fire protection. The non-welded columns with mechanical strip connections showed 15% higher strength under ambient temperature and resisted 40 min longer under elevated temperature compared to the typical welded column. Also, local buckling by compression was barely observed in the non-welded columns, whereas a large buckling was shown in the typical welded column under both ambient and elevated temperatures. It is concluded that non-welded columns with mechanical strip connections provide a viable way to avoid the welding problems of typical concrete-filled-tube columns, providing good performance under fire without fire protection.
Article navigation
January 2020
Research Article|
August 17 2018
Fire behaviour of non-welded concrete-filled-tube columns with strip connectors
Hyun Kang, PhD;
Hyun Kang, PhD
Post-Doctoral Research Fellow, Department of Architectural Engineering, University of Seoul, Seoul, Korea
Search for other works by this author on:
Jungmin Lee, MSc;
Jungmin Lee, MSc
Post-Master Researcher, Department of Architectural Engineering, University of Seoul, Seoul, Korea
Search for other works by this author on:
Minsu Kim, MSc;
Minsu Kim, MSc
Employee, Department of Structural Engineering 2, Yunwoo Structural Engineers Co. Ltd, Seoul, Korea
Search for other works by this author on:
In-Wook Heo, MSc;
In-Wook Heo, MSc
PhD student, Department of Architectural Engineering, University of Seoul, Seoul, Korea
Search for other works by this author on:
Jae Yuel Oh, PhD;
Jae Yuel Oh, PhD
Chief Researcher, Department of Research and Development, Sejin R&S, Seoul, Korea
Search for other works by this author on:
Kang Su Kim, PhD
Kang Su Kim, PhD
Professor, Department of Architectural Engineering, University of Seoul, Seoul, Korea (corresponding author: kangkim@uos.ac.kr)
Search for other works by this author on:
Publisher: Emerald Publishing
Received:
September 08 2016
Accepted:
July 04 2018
Online ISSN: 1751-7702
Print ISSN: 0965-0911
ICE Publishing: All rights reserved
2018
Proceedings of the Institution of Civil Engineers - Structures and Buildings (2020) 173 (1): 17–30.
Article history
Received:
September 08 2016
Accepted:
July 04 2018
Citation
Kang H, Lee J, Kim M, Heo I, Oh JY, Kim KS (2020), "Fire behaviour of non-welded concrete-filled-tube columns with strip connectors". Proceedings of the Institution of Civil Engineers - Structures and Buildings, Vol. 173 No. 1 pp. 17–30, doi: https://doi.org/10.1680/jstbu.16.00170
Download citation file:
New and popular articles
Suggested Reading
The effect of reinforcement ratios on composite slabs in fire
Proceedings of the Institution of Civil Engineers - Structures and Buildings (July,2012)
Fire performance of metal-free timber connections
Proceedings of the Institution of Civil Engineers - Construction Materials (May,2015)
Post-fire reliability analysis of concrete beams retrofitted with CFRPs: a new approach
Proceedings of the Institution of Civil Engineers - Structures and Buildings (October,2019)
Large-scale fire test of unprotected cellular beam acting in membrane action
Proceedings of the Institution of Civil Engineers - Structures and Buildings (July,2012)
The mechanics of inelastic buckling using a Shanley-like model
Proceedings of the Institution of Civil Engineers - Engineering and Computational Mechanics (June,2011)
Related Chapters
Behaviour of Rectangular Rc Columns Retrofitted by Fibre Reinforced Polymers Under Axial and Cyclic Loading
Role of Concrete Bridges in Sustainable Development: Proceedings of the International Symposium held at the University of Dundee, Scotland, UK on 3–4 September 2003
USE OF COMPOSITE STRUCTURES IN A BUILDING ABOVE A METRO STATION
Innovations and Developments In Concrete Materials And Construction: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 9–11 September 2002
4.2 Performance and application of a design-oriented stress-strain model for FRP-confined concrete
Advanced polymer composites for structural applications in construction: Proceedings of the first international conference, held at Southampton University, UK, on 15–17 April 2002
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.