This paper describes a three-dimensional (3D) finite-element (FE) model developed to assess the seismic behaviour of a novel prefabricated beam-to-beam connection termed a double-bolted flush end-plate beam (DBFEB) splice connection under cyclic loading. The seismic response was analysed and evaluated in terms of the hysteretic behaviour, rigidity, resistance degradation, ductility, energy dissipation capacity and equivalent damping coefficient. It is shown that the required performance can be achieved by controlling the end-plate thickness as well as the bolt grade and diameter; these parameters were therefore chosen as the key geometric variables investigated here for parametric study. Also this type of new connection provided an appropriate level of strength and stiffness and can be categorised as a semi-rigid connection based on Eurocode 3, as investigated in the previous work published by the authors. Subsequently, a bilinear simplified hysteretic moment–rotation (M–θ) model for the DBFEB connection was proposed and its defining parameters were obtained by conducting several parametric analyses on the results of the 45 most proportional 3D FE model specimens of this type of connection that were selected for the regression analysis.
Article navigation
February 2020
Research Article|
March 01 2019
Seismic performance evaluation of a novel bolted flush end-plate beam splice connection
Hamed Keikha, MSc
;
Hamed Keikha, MSc
PhD candidate, School of Civil Engineering, Iran University of Science and Technology, Tehran, Iran (corresponding author: keikha@alum.sharif.edu, keikha.sut@gmail.com)
Search for other works by this author on:
Massood Mofid, PhD
Massood Mofid, PhD
Professor, Department of Civil Engineering, Sharif University of Technology, Tehran, Iran
Search for other works by this author on:
Publisher: Emerald Publishing
Received:
May 16 2018
Accepted:
November 01 2018
Online ISSN: 1751-7702
Print ISSN: 0965-0911
ICE Publishing: All rights reserved
2019
Proceedings of the Institution of Civil Engineers - Structures and Buildings (2020) 173 (2): 109–127.
Article history
Received:
May 16 2018
Accepted:
November 01 2018
Citation
Keikha H, Mofid M (2020), "Seismic performance evaluation of a novel bolted flush end-plate beam splice connection". Proceedings of the Institution of Civil Engineers - Structures and Buildings, Vol. 173 No. 2 pp. 109–127, doi: https://doi.org/10.1680/jstbu.18.00087
Download citation file:
New and popular articles
Suggested Reading
Three-dimensional non-linear seismic analysis of asymmetric structures on elastic soil
Proceedings of the Institution of Civil Engineers - Structures and Buildings (November,2020)
Attenuation relationship for inelastic earthquake spectra in Iran
Proceedings of the Institution of Civil Engineers - Structures and Buildings (May,2015)
On the use of Rayleigh damping for seismic analysis
Proceedings of the Institution of Civil Engineers - Engineering and Computational Mechanics (December,2009)
Dynamics of in-plane arch rocking: an energy approach
Proceedings of the Institution of Civil Engineers - Engineering and Computational Mechanics (September,2010)
A passive shape-memory-alloy–rubber-bearing seismic isolator for offshore platforms
Proceedings of the Institution of Civil Engineers - Structures and Buildings (August,2021)
Related Chapters
Beyond Deductivism
Including a Symposium on Bruce Caldwell’s Beyond Positivism After 35 Years
Behaviour of reinforced self-consolidating concrete frames
ICE Themes Self-Compacting Concrete
Measurement and modelling of conduction in carbon fibre-cement composites
ICE Themes Smart Concrete
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.