Proceedings of the Institution of Civil Engineers - Structures and Buildings 1–25.
Published: 04 September 2026
... (afaq.ahmad@oslomet.no) 13 02 2026 24 06 2026 © 2026 Emerald Publishing Limited 2026 Emerald Publishing Limited Licensed re-use rights only artificial intelligence corrosion field testing & monitoring heavy metals maintenance & inspection service life site...
Journal Articles
Journal Articles
Journal Articles
Proceedings of the Institution of Civil Engineers - Structures and Buildings (2025) 178 (2): 123–134.
Published: 06 February 2025
... ( a ) The last operation can be repeated in successive iterations, called epochs, until the acceptable level of estimated error is reached (Strączkiewicz and Barszcz, 2016). 29 11 2023 12 07 2024 Emerald Publishing Limited: All rights reserved 2025 field testing & monitoring...
Journal Articles
Journal Articles
Journal Articles
Journal Articles
Proceedings of the Institution of Civil Engineers - Structures and Buildings (2023) 176 (7): 487–499.
Published: 29 April 2021
.... Between the first and second mode, the MAC was found to be 0.065; between the first and third mode MAC = 0.024 and between the second and third modes MAC = 0.052. buildings, structures & design dynamics field testing & monitoring According to current construction practice...
Journal Articles
Proceedings of the Institution of Civil Engineers - Structures and Buildings (2023) 176 (8): 630–645.
Published: 17 March 2021
... Publishing Limited: All rights reserved 2021 cooling towers field testing & monitoring wind loading & aerodynamics Non-stationary features of natural winds, which might cause aggravated wind effects on structures, have drawn the attention of the wind engineering community in recent...
Journal Articles
Proceedings of the Institution of Civil Engineers - Structures and Buildings (2022) 175 (6): 486–499.
Published: 04 October 2020
... undesirable air bubbles were smoothed out with a hand trowel, after which the FRP was air-cured for 3 days. composite structures concrete structures field testing & monitoring Figure 1. Schematic illustration of beam specimen: (a) plan; (b) elevation A thin vertical mid-span...
Journal Articles
Journal Articles
Proceedings of the Institution of Civil Engineers - Structures and Buildings (2022) 175 (6): 500–512.
Published: 21 July 2020
... the in-service footbridge performance to be assessed based on current standards and design guidelines. dynamics field testing & monitoring footbridges Several footbridges constructed in recent years suffer from vibration amplification because their fundamental natural frequencies are close...
Journal Articles
Proceedings of the Institution of Civil Engineers - Structures and Buildings (2021) 174 (12): 981–991.
Published: 11 December 2019
... reserved 2019 field testing & monitoring tunnels & tunnelling underwater engineering In recent years, many tunnels have been constructed under rivers and seas in China, and more than a dozen underwater tunnels are under construction or are in the planning stage. However...
Journal Articles
Journal Articles
Proceedings of the Institution of Civil Engineers - Structures and Buildings (2019) 172 (6): 451–466.
Published: 16 November 2018
... responses associated with light rail trains. Several transit agencies have developed design guidelines using their own live load models. A standard live load model for light rail transit is required to achieve uniform design outcomes. bridges field testing & monitoring railway systems Train...
Journal Articles
Proceedings of the Institution of Civil Engineers - Structures and Buildings (2020) 173 (1): 63–75.
Published: 03 April 2018
...: (a) column details; (b) detail of steel joints; (c) specimens C1 and C2 concrete structures field testing & monitoring safety & hazards The Canadian Occupational Health and Safety Regulations state that any work involving precast and tilt-up concrete is high risk (OHS, 2007...
Journal Articles
Proceedings of the Institution of Civil Engineers - Structures and Buildings (2018) 171 (12): 917–930.
Published: 14 March 2018
... consecutive frames and the neighbouring pixels have similar motion. The image motions are derived using the following equation 03 09 2017 22 11 2017 ICE Publishing: All rights reserved 2018 bridges field testing & monitoring noise To find the most appropriate tracking...
Journal Articles
Proceedings of the Institution of Civil Engineers - Structures and Buildings (2017) 170 (12): 885–900.
Published: 06 June 2017
... buildings, structures & design concrete structures field testing & monitoring This paper describes the implementation of a real-time structural health monitoring (SHM) scheme on a new building (the Human Biology Building (HBB)) under construction at the National University of Ireland...
Journal Articles
Proceedings of the Institution of Civil Engineers - Structures and Buildings (2017) 170 (10): 722–734.
Published: 26 May 2017
... behaviour of structural members by concentrating it in the disposable fuse (Martinez-Romero, 1993). Extensive research has been conducted to develop explicit procedures for the implementation of dampers in buildings (Ramirez et al., 2002 ; Whittaker et al., 2003). field testing...
Journal Articles
Proceedings of the Institution of Civil Engineers - Structures and Buildings (2017) 170 (4): 303–310.
Published: 27 February 2017
... constants E3 and G23 were obtained in this study as follows. 11 03 2016 18 01 2017 ICE Publishing: All rights reserved 2017 computational mechanics field testing & monitoring strength & testing of materials Table 1...