A better understanding of the surface oxide film on biodegradable metals could lead to the design of smarter, surface-responsive biodegradable stents with good biocompatibility and controlled degradation rates at different stages of implantation. In this study, the surface finish of zinc was manipulated through different material processing conditions, including oxidation, electropolishing and anodization. Implant wires with oxide films of varying surface characteristics were degraded in a living organism by using a rodent model to understand their response to a biological endovascular environment. It was found that the degradation rate was mainly dependent on the quality and stability of oxide film. Defects/cracks in the oxide film structure appear to serve as local corrosion sites, and their increased density accelerates the biocorrosion rate.
Article navigation
1 September 2016
Research Article|
October 10 2016
Importance of oxide film in endovascular biodegradable zinc stents Available to Purchase
Adam J. Drelich;
Adam J. Drelich
Undergraduate student
Department of Materials Science and Engineering, Michigan Technological University, Houghton, MI, USA
Search for other works by this author on:
Patrick K. Bowen, PhD;
Patrick K. Bowen, PhD
Graduate student
Department of Materials Science and Engineering, Michigan Technological University, Houghton, MI, USA
Search for other works by this author on:
Leslie LaLonde, BS;
Leslie LaLonde, BS
Undergraduate student
Department of Biomedical Engineering, Michigan Technological University, Houghton, MI, USA
Search for other works by this author on:
Jeremy Goldman, PhD;
Jeremy Goldman, PhD
Professor
Department of Biomedical Engineering, Michigan Technological University, Houghton, MI, USA
Search for other works by this author on:
Jaroslaw W. Drelich, PhD
Jaroslaw W. Drelich, PhD
*
Professor
Department of Materials Science and Engineering, Michigan Technological University, Houghton, MI, USA
*Corresponding author e-mail address: jwdrelic@mtu.edu
Search for other works by this author on:
*Corresponding author e-mail address: jwdrelic@mtu.edu
Publisher: Emerald Publishing
Received:
August 12 2016
Accepted:
September 21 2016
Online ISSN: 2050-6260
Print ISSN: 2050-6252
ICE Publishing: All rights reserved
2016
Surface Innovations (2016) 4 (3): 133–140.
Article history
Received:
August 12 2016
Accepted:
September 21 2016
Citation
Drelich AJ, Bowen PK, LaLonde L, Goldman J, Drelich JW (2016), "Importance of oxide film in endovascular biodegradable zinc stents". Surface Innovations, Vol. 4 No. 3 pp. 133–140, doi: https://doi.org/10.1680/jsuin.16.00014
Download citation file:
Suggested Reading
Effect of gold nanoparticle size and surface coating on human red blood cells
Bioinspired, Biomimetic and Nanobiomaterials (May,2016)
Aspirin-loaded P(3HO)/P(3HB) blend films: potential materials for biodegradable drug-eluting stents
Bioinspired, Biomimetic and Nanobiomaterials (September,2013)
Bioactivity, cytocompatibility and effect of cells on degradation behavior of Mg–2Zn–2Gd alloy
Nanomaterials and Energy (July,2019)
Fabrication of vascular-like conduits in gel structures by robotic needle navigation system
Bioinspired, Biomimetic and Nanobiomaterials (February,2026)
Protein-mediated hydroxyapatite composite layer formation on nanotubular titania
Bioinspired, Biomimetic and Nanobiomaterials (June,2015)
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.
