In the present work air demand in a gated tunnel with a circular cross-section was studied experimentally. Effects of gate opening, relative depth (i.e. ratio of flow depth to tunnel diameter) and head losses in the air vent, as well as along the air passage from the tunnel outlet, on air demand were studied. It was concluded that when losses in the air vent increase, flow of air begins from the tunnel outlet. A relationship is suggested for the minimum sub-atmospheric pressure after the gate at which air flow starts from the tunnel outlet. Measurements showed that with a relative depth of less than 40%, even when the vent was fully closed, air was supplied from the tunnel outlet. In this condition higher negative pressures were recorded after the gate. The present work revealed the importance of head losses along the air passage in the tunnel as well as the head losses in the air vent on vent air discharge. These factors are not considered in empirical equations for estimation of vent air discharge.
Article navigation
April 2008
Research Article|
April 01 2008
Experimental study of air demand in high head gated tunnels Available to Purchase
K. Safavi, MSc;
K. Safavi, MSc
Senior Research Engineer
Water Research Institute,
Tehran, Iran
Search for other works by this author on:
A. R. Zarrati, MSc, DIC, PhD;
A. R. Zarrati, MSc, DIC, PhD
Associate Professor
Department of Civil and Environmental Engineering, Amirkabir University of Technology,
Tehran, Iran
Search for other works by this author on:
J. Attari, MSc, DIC, PhD
J. Attari, MSc, DIC, PhD
Assistant Professor
Department of Water Engineering, Power and Water, University of Technology,
Tehran, Iran
Search for other works by this author on:
Publisher: Emerald Publishing
Received:
June 11 2007
Accepted:
November 27 2007
Online ISSN: 1751-7729
Print ISSN: 1741-7589
© 2008 Thomas Telford Ltd
2008
Proceedings of the Institution of Civil Engineers - Water Management (2008) 161 (2): 105–111.
Article history
Received:
June 11 2007
Accepted:
November 27 2007
Citation
Safavi K, Zarrati AR, Attari J (2008), "Experimental study of air demand in high head gated tunnels". Proceedings of the Institution of Civil Engineers - Water Management, Vol. 161 No. 2 pp. 105–111, doi: https://doi.org/10.1680/wama.2008.161.2.105
Download citation file:
Suggested Reading
Improving Forecasting Accuracy through Trading Day Adjustment
International Journal of Operations & Production Management (January,1989)
Finite element analysis of saturation effects in a squirrel cage electrical machine
COMPEL (December,1996)
The simplified model of the Class E inverter with the PWL model of the MOSFET turn off
COMPEL (June,1997)
A human resources model for excellence in global organization performance
Management Decision (February,2000)
A New Approach to Situational Leadership
Leadership & Organization Development Journal (April,1985)
Related Chapters
Meta-Analytic Methods
Safe Mobility: Challenges, Methodology and Solutions
Analyzing Enacted Curriculum: Seven Lessons Learned From Collecting, Coding, and Analyzing Large Sets of Qualitative Data
Lessons Learned From Research on Mathematics Curriculum
WATER-CEMENT RATIO LAW AND SILICA FUME CONCRETE MIX DESIGN
Cement Combinations for Durable Concrete: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 5–7 July 2005
Recommended for you