The hardware, software and systems components of a Clinical Research ECG Station using an IBM‐1800 computer under the Multi‐Programming Executive System (MPX) is described. The twelve classic leads and the three Frank leads of the patient‐acquired ECG are sent in analog form over telephone lines via Marquette Electronics' carts and receiving interface, which modulate and demodulate the signal for computer acquisition, subsequent analog to digital conversion, and analysis. The Smith‐Mayo program (on the Frank leads) initially used, has been augmented by a Hahnemann‐developed, twelve‐lead analysis program to improve the interpretive portion of the program in the areas of LVH, Infarctious, Bundle Blocks, etc. A truly innovative portion of the system is the creation of a computer‐driven microfilm system which produces aperture cards. These contain all the graphical input on microfilm, plus graphs of the two‐dimensional vector curves and the appropriate patient identification information. Archive tapes of the digitized ECG are kept as a data repository for (1) the constant reworking of the analysis program, (2) the development of proper comparison programs, and (3) the research potential of using existing Probabilistic‐Statistical Differential Diagnosis methods to quest the nature of what symptomatic information is necessary to optimize the diagnostic process in the ECG area.
Article navigation
1 April 1972
Review Article|
April 01 1972
DEVELOPING A COMPUTER ECG RESEARCH STATION
P.A. SCHEINOK;
P.A. SCHEINOK
Computer Center, Hahnemann Medical College and Hospital, Philadelphia, Pennsylvania
Search for other works by this author on:
K.W. THUM;
K.W. THUM
Computer Center, Hahnemann Medical College and Hospital, Philadelphia, Pennsylvania
Search for other works by this author on:
M.B. REICH;
M.B. REICH
Computer Center, Hahnemann Medical College and Hospital, Philadelphia, Pennsylvania
Search for other works by this author on:
A. KRAZESKY;
A. KRAZESKY
Computer Center, Hahnemann Medical College and Hospital, Philadelphia, Pennsylvania
Search for other works by this author on:
L.S. DREIFUS
L.S. DREIFUS
Division of Cardiology, Department of Medicine, Hahnemann Medical College and Hospital, Philadelphia
Search for other works by this author on:
Publisher: Emerald Publishing
Online ISSN: 1758-7883
Print ISSN: 0368-492X
© MCB UP Limited
1972
Kybernetes (1972) 1 (4): 221–229.
Citation
SCHEINOK P, THUM K, REICH M, KRAZESKY A, DREIFUS L (1972), "DEVELOPING A COMPUTER ECG RESEARCH STATION". Kybernetes, Vol. 1 No. 4 pp. 221–229, doi: https://doi.org/10.1108/eb005313
Download citation file:
New and popular articles
Suggested Reading
ECG/LAB: A MERGER OF TWO SYSTEMS ON A MINI‐MIDI COMPUTER COMPLEX
Kybernetes (March,1973)
U.S. Patent Specifications
Aircraft Engineering (March,1941)
Marketing an established institutional repository: Marquette Libraries’ research stewardship survey
Library Hi Tech News (August,2014)
How to develop successful and ethical investment analysts: Marquette University’s Applied Investment Management program
Managerial Finance (May,2019)
Comfortable textile-based electrode for wearable electrocardiogram
Sensor Review (January,2015)
Related Chapters
Compressive sensing-based wireless sensors and sensor networks for structural health monitoring
Transforming the Future of Infrastructure through Smarter Information: Proceedings of the International Conference on Smart Infrastructure and ConstructionConstruction, 27–29 June 2016
References
Experiences in Teaching Business Ethics
Wellness as a Gateway to Misinformation, Disinformation and Conspiracy
Wellness Culture: How the Wellness Movement has Been Used to Empower, Profit and Misinform
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.