The classical models for volumelry of the heart's left ventricle are based upon the simplifying assumption that this chamber is an ellipsoid. This simplification is needed in order to manually process radiographic images of the left ventricle. Computer processing of these images allows a much more realistic approach by associating with the left ventricle a topologically deformed ellipsoid, which approximately is its actual shape. This is the model proposed and analysed in this paper; from this model an algorithm is derived for accurately calculating left ventricle volumetry. This algorithm is simple enough to be implemented on most microcomputers provided with an analog‐to‐digital converter, like joystick, or a magic pen or digitizer. By this procedure the assessing of hemodynamical parameters can be performed in a few minutes with a great improvement in accuracy as compared with classical methods.
Article navigation
1 March 1987
Review Article|
March 01 1987
A MODEL FOR ACCURATE CARDIAC VOLUMETRY, Part I: THEORETICAL FOUNDATIONS
ALEJANDRO B. ENGEL;
ALEJANDRO B. ENGEL
USACH—Depto Ingenieria Informatica, Casilla 10233, Santiago (Chile)
Search for other works by this author on:
SILVIO JOSE BEZERRA;
SILVIO JOSE BEZERRA
UNICAMP IMECC—Depto Matematica Aplicada, Caixa Postal 6160, 13.100 Campinas (S.p.—Brazil)
Search for other works by this author on:
SIGUEMITUSO ARIE
SIGUEMITUSO ARIE
USP‐INCOR—Departamento de Catererismo, Av. Reboucas, Sao Paulo (S.P.—Brazil)
Search for other works by this author on:
Publisher: Emerald Publishing
Online ISSN: 1758-7883
Print ISSN: 0368-492X
© MCB UP Limited
1987
Kybernetes (1987) 16 (3): 183–185.
Citation
ENGEL AB, JOSE BEZERRA S, ARIE S (1987), "A MODEL FOR ACCURATE CARDIAC VOLUMETRY, Part I: THEORETICAL FOUNDATIONS". Kybernetes, Vol. 16 No. 3 pp. 183–185, doi: https://doi.org/10.1108/eb005767
Download citation file:
Suggested Reading
Communications: A Model for Accurate Cardiac Volumetry: Experimental Results on the Normal Heart
Kybernetes (June,1990)
Knitted cardiac mesh to support left ventricular hypertrophy: an in vivo experimental study: supporting left ventricular hypertrophy using cardiac support mesh
Research Journal of Textile and Apparel (October,2021)
Noninvasive cardiac source imaging from potential and magnetic field data
COMPEL (September,1999)
A collagen membrane-based engineered heart tissue improves cardiac function in ischemic rat hearts
Bioinspired, Biomimetic and Nanobiomaterials (March,2013)
Related Chapters
Recurrence of Intravenous Leiomyomatosis: A Rare Cause of the Obstruction of the Right Heart
Proceedings of MICoMS 2017
Network-Based Transformation of Cardiac Care in New Zealand
Reconfiguring the Ecosystem for Sustainable Healthcare
Continuous Cardiac Monitoring Policy Implementation: Three-year Sustained Decrease of Hospital Resource Utilization
Structural Approaches to Address Issues in Patient Safety
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.
