Skip to Main Content
Article navigation
Purpose

The purpose of this paper is to detect and control the liquid‐level of stereolithography apparatus precisely.

Design/methodology/approach

A brightness‐variable laser source is adopted to remove the computational error of divider and a closed‐loop circuit is set to measure the terminal voltage directly proportional to the output current of photosensitive devices. It employs a sinking‐block device to control the liquid‐level.

Findings

The precise calibration result of this detecting device indicates that the resolution of the liquid‐level detection can reach ±1.5 μm.

Originality/value

This sinking‐block style liquid‐level control device can allow for the liquid‐level wave reduced from ±45 to ±15 μm.

You do not currently have access to this content.
Don't already have an account? Register

Purchased this content as a guest? Enter your email address to restore access.

Please enter valid email address.
Email address must be 94 characters or fewer.
Pay-Per-View Access
$41.00
Rental

or Create an Account

Close Modal
Close Modal

Gift article access

As a benefit of your subscription, you can share temporary access to restricted articles.

Each link will stop working after 30 days or 10 uses. You may create up to 10 links in a 30 day period.

Please sign in to your personal account to gift article access.

Register

Gift article access

As a benefit of your subscription, you can share temporary access to restricted articles.

Each link will stop working after 30 days or 10 uses. You may create up to 10 links in a 30 day period.

Gift articles remaining: --

Gift article access

Each link will stop working after 30 days or 10 uses. You may create up to 10 links in a 30 day period.

Gift articles remaining: --

Gift article access

As a benefit of your subscription, you can share temporary access to restricted articles.

Each link will stop working after 30 days or 10 uses.

You have reached the limit of 10 links within a 30 day period.