Skip to Main Content
Article navigation
Purpose

This study aims to optimize the process parameters of ZPrinter® 450 for measured porosity (MP) and compressive strength (CS) of calcium sulfate-based porous bone scaffold using Taguchi approach.

Design/methodology/approach

Initially, a porous scaffold with smallest pore size that can be de-powdered completely is identified through a pilot study. Five printing parameters, namely, layer thickness (LT), build orientation (BO), build position (BP), delay time (DT) and binder saturation (BS), each at three levels have been optimized for MP and CS of the fabricated scaffolds using L27 orthogonal array (OA), signal-to-noise ratio and analysis of variance (ANOVA).

Findings

The scaffolds with 600 µm pores could be de-powdered completely. Optimum levels of parameters are LT2, BO1, BP2, DT1 and BS1 for MP and LT1, BO1, BP2, DT1 and BS2 for CS. The ANOVA reveals that the BS (49.12%) is the most and BP (8.34%) is the least significant parameter for MP. LT (50.84%) is the most, BO (33.79%) is second most and DT (2.59%) is the least significant parameter for CS. Taguchi confirmation test and linear regression models indicate a good agreement between predicted and experimental values of MP and CS. The experimental values of MP and CS at the optimum levels of parameters are found 38.12% and 1.29 MPa, respectively.

Originality/value

The paper presents effect of process parameters of ZPrinter® 450 on MP and CS of calcium sulfate-based porous scaffolds. Results may be used as guideline for powder bed binder jetting three-dimensional printing of ceramic scaffolds.

Licensed re-use rights only
You do not currently have access to this content.
Don't already have an account? Register

Purchased this content as a guest? Enter your email address to restore access.

Please enter valid email address.
Email address must be 94 characters or fewer.
Pay-Per-View Access
$41.00
Rental

or Create an Account

Close Modal
Close Modal