Article navigation
Purpose

The purpose of this paper was to develop a chemo-resistive sensor based on TiO2–WO3 composite material to detect and estimate ethylene released from the fruit ripening process to ensure food safety.

Design/methodology/approach

The ethylene sensor has been fabricated using TiO2–WO3 composite material through the sol-gel method.

Findings

The sensitivity of the sensor obtained using the pre-calibrated ethylene is found to be 46.2 per cent at 200 ppm ethylene concentration, and the proposed sensor could measure 8 ppm as the lowest concentration.

Originality/value

The sensor was tested for continuous ethylene detection during natural ripening of fruits and hence is useful for ensuring food safety through discrimination of the type of fruit ripening. A TiO2–WO3 composite ethylene sensor is developed for the first time.