Fibre reinforced polymer (FRP) materials are currently used for concrete structures in areas where corrosion problems are serious. Recent applications of FRP rebars in normal reinforced concrete structures in fact cannot fully utilise the strength of FRP. A more rational use of FRP would be in the area of prestressed concrete (PC) structures. In spite of the superb strength provision of FRP tendons over steel tendons, use of FRP PC members is often questioned by practising design engineers. This is largely due to the brittleness of FRP tendons and lack of ductility in FRP RC structures. Recent research has demonstrated some important findings in promoting the confidence of adopting FRP RC beams. This paper reviews some recent work on the use of FRP in PC structures. Future possible research areas are also highlighted.
Article navigation
Research Article|
May 01 2003
Fibre reinforced polymer materials for prestressed concrete structures
H.Y. Leung;
H.Y. Leung
Lecturer, Department of Building and Construction, City University of Hong Kong, Hong Kong SAR, China
Search for other works by this author on:
R.V. Balendran;
R.V. Balendran
Associate Professor, Department of Building and Construction, City University of Hong Kong, Hong Kong SAR, China
Search for other works by this author on:
T. Maqsood;
T. Maqsood
Research student, Department of Building and Construction, City University of Hong Kong, Hong Kong SAR, China
Search for other works by this author on:
A. Nadeem;
A. Nadeem
Research student, Department of Building and Construction, City University of Hong Kong, Hong Kong SAR, China
Search for other works by this author on:
T.M. Rana;
T.M. Rana
Research Assistant, Department of Building and Construction, City University of Hong Kong, Hong Kong SAR, China
Search for other works by this author on:
W.C. Tang
W.C. Tang
Research Assistant, Department of Building and Construction, City University of Hong Kong, Hong Kong SAR, China
Search for other works by this author on:
Publisher: Emerald Publishing
Online ISSN: 1758-6844
Print ISSN: 0263-080X
© MCB UP Limited
2003
Structural Survey (2003) 21 (2): 95–101.
Citation
Leung H, Balendran R, Maqsood T, Nadeem A, Rana T, Tang W (2003), "Fibre reinforced polymer materials for prestressed concrete structures". Structural Survey, Vol. 21 No. 2 pp. 95–101, doi: https://doi.org/10.1108/02630800310479098
Download citation file:
267
Views
New and popular articles
Suggested Reading
Bricks: Properties and Classifications
Structural Survey (August,1994)
Strength and durability performance of HPC incorporating pozzolans at elevated temperatures
Structural Survey (October,2002)
Estimating the elastic modulus of concrete made with artificially manufactured lightweight aggregates
Structural Survey (June,1995)
Sealants for joints in buildings
Structural Survey (March,1992)
Dirt in mechanical building services systems
Structural Survey (January,1991)
Related Chapters
ENVIRONMENTAL INFORMATION ON CONCRETE
Challenges of Concrete Construction: Volume 5, Sustainable Concrete Construction: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 9–11 September 2002
THE GLOBAL CHALLENGE OF RECYCLED CONCRETE
Sustainable Construction: Use of Recycled Concrete Aggregate: Proceedings of the International Symposium organised by the Concrete Technology Unit, University of Dundee and held at the Department of Trade and Industry Conference Centre, London, UK on 11 – 12 November 1998
Specifying bitumens and checking their quality
The Shell Bitumen Handbook, 6th edition
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.
