The electro-chemical reaction of corrosion in reinforced concrete (RC) under the effect of varying chloride and temperature is influenced by several construction material parameters, some of which have been overlooked in past research studies. Furthermore, there exists a difference of opinion between various researchers and there is limited data for high temperatures up to 60°C and high chloride concentration up to 10% total chlorides. The objective of the present research was to investigate the severe effects of chloride and temperature on the corrosion of RC material by developing realistic construction material models and performing actual field condition experiments. The experiments consisted of 24 specimens using Portland cement concrete mixed with 0·0, 0·025, 0·25, 0·6, 1·0, 1·82, 3·65, 6·0, 8·0 and 10·0% chloride (NaCl: 0–16.5% by mass of cement) and three temperature conditions of 20, 40 and 60°C, respectively. The concrete material durability model ‘DuCOM’ developed by the authors' research group was used as a computational platform on which the corrosion-based RC material performance and technology was examined in both space and time domains. The experimental results were found to be in close agreement with the material model developed in the present study.
Article navigation
August 2011
Research Article|
June 10 2011
Corrosion in RC construction under chloride and hot weather
Raja Rizwan Hussain, PhD;
Raja Rizwan Hussain, PhD
1
Assistant Professor, CoE-CRT, Civil Engineering Department, King Saud University
Saudi Arabia
Search for other works by this author on:
Tetsuya Ishida, PhD;
Tetsuya Ishida, PhD
2
Associate Professor, Civil Engineering Department, University of Tokyo
Japan
Search for other works by this author on:
Muhammad Wasim, BE
Muhammad Wasim, BE
3
Research engineer, CoE-CRT, Civil Engineering Department, King Saud University
Saudi Arabia
Search for other works by this author on:
Publisher: Emerald Publishing
Received:
January 12 2010
Accepted:
April 20 2010
Online ISSN: 1747-6518
Print ISSN: 1747-650X
ICE Publishing: All rights reserved
2011
Proceedings of the Institution of Civil Engineers - Construction Materials (2011) 164 (4): 191–198.
Article history
Received:
January 12 2010
Accepted:
April 20 2010
Citation
Hussain RR, Ishida T, Wasim M (2011), "Corrosion in RC construction under chloride and hot weather". Proceedings of the Institution of Civil Engineers - Construction Materials, Vol. 164 No. 4 pp. 191–198, doi: https://doi.org/10.1680/coma.1000007
Download citation file:
New and popular articles
Suggested Reading
Shear strength model for fibre reinforced polymer shear reinforced concrete beams
Proceedings of the Institution of Civil Engineers - Structures and Buildings (March,2013)
Cube, cylinder, core and pull-off strength relationships
Proceedings of the Institution of Civil Engineers - Structures and Buildings (November,2013)
Shrinkage cracking of amorphous metallic fibre-reinforced concrete
Proceedings of the Institution of Civil Engineers - Structures and Buildings (April,2015)
Evaluation of tension lap splices for code provisions
Proceedings of the Institution of Civil Engineers - Structures and Buildings (September,2012)
Cracking and tension zone behaviour in RC flexural members
Proceedings of the Institution of Civil Engineers - Structures and Buildings (June,2007)
Related Chapters
CRITERIA FOR AND PREDICTION OF LIMIT STATES OF DEGRADATION OF REINFORCED CONCRETE STRUCTURES
Role of Concrete in Nuclear Facilities
Moorgate Shaft Base Slab, design, detailing and construction
Crossrail Project: Infrastructure design and construction
ASSESSMENT OF CORROSION DAMAGED REINFORCED CONCRETE STRUCTURES
Role of Concrete in Nuclear Facilities
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.