Chlorite ion is a by-product of chlorine dioxide and is typically present at concentrations ranging from 0.3 to 1.0 mg/L in the finished water of systems using this oxidant in the treatment process. When combined with free chlorine, these two reactive ions have been shown to react to form chlorine dioxide. Chlorine dioxide concentrations formed in tap water (either in the distribution system or during domestic use of tap water, such as laundry bleaching) can off-gas in a home and react with volatile organic compounds associated with new carpets and furniture fabrics, resulting in cat-urine type odors and customer complaints. The objective of this study was to determine if chlorine dioxide is formed when the high concentrations of hypochlorite ion that are used in laundry bleaching operations are contacted with residual chlorite ion that is present in tap water of systems using chlorine dioxide at the treatment plant. If chlorine dioxide is forming under these circumstances, it could be a cause of seemingly random odor complaints periodically received by water utilities using chlorine dioxide. The formation of chlorine dioxide was found to be negligible under simulated laundry bleaching conditions. The key factor in chlorine dioxide formation was found to be pH. When chlorine is added as a base (e.g., sodium hypochlorite), the resulting pH is high enough to suppress chlorine dioxide formation.Key words: chlorine dioxide, chlorite ion, hypochlorite ion, re-formation, odors.
Article navigation
1 July 2003
Research Article|
July 01 2003
Formation of chlorine dioxide under laundry bleaching conditions
Publisher: Emerald Publishing
Online ISSN: 1496-256X
Print ISSN: 1496-2551
Journal of Environmental Engineering and Science (2003) 2 (4): 293–297.
Citation
Carr M, Carlson K, Gregory D (2003), "Formation of chlorine dioxide under laundry bleaching conditions". Journal of Environmental Engineering and Science, Vol. 2 No. 4 pp. 293–297, doi: https://doi.org/10.1139/s03-020
Download citation file:
Suggested Reading
Non-enzymatic degradation of chlorofluorocarbon 113 using cyanocobalamin under anaerobic conditions
Journal of Environmental Engineering and Science (July,2004)
Impact of organic waste amendments on soil hydraulic properties and on water partitioning
Journal of Environmental Engineering and Science (May,2006)
Fouling assessment in a municipal water reclamation reverse osmosis system as related to concentration factor
Journal of Environmental Engineering and Science (January,2004)
Particle penetration through rectangular-shaped cracks
Journal of Environmental Engineering and Science (August,2006)
Ozone treatment for the degradation of resin and unsaturated fatty acids at low temperatures
Journal of Environmental Engineering and Science (August,2006)
Related Chapters
Health, safety and welfare
Initial Professional Development for Civil Engineers
The Experience of Environmental Barriers among Adults with Disabilities: A National Description
Environmental Contexts and Disability
Ice
Innovate to Survive: Engineers for a One Planet Future
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.
