Computational fluid dynamics (CFD) modeling and full-scale tracer tests (using barium or fluoride) were used to determine the baffle factors of clearwells at three Canadian water treatment facilities (two in Ottawa, Ontario, and one in Peterborough, Ontario). A variety of clearwell baffling configurations and a range of flow rates (35 to 257 MLD) were considered. Two-dimensional CFD modeling (no depth dimension) was conducted using commercially available software (Fluent 6.0®). Virtual particle tracking allowed simulation of the residence time distribution for each clearwell configuration and flow rate condition. The baffle factors (t10/θ) derived from the CFD modeling closely matched the values obtained from full-scale tracer testing (<10% difference in most cases). The results of the study suggest that CFD modeling can be a reliable alternative to tracer testing for determining clearwell residence times and can thereby provide improved estimates of chemical disinfection performance and disinfection by-product formation. Key words: computational fluid dynamics, tracer, clearwell, baffle factor, barium, fluoride, disinfection, drinking water.
Article navigation
1 November 2006
Research Article|
November 01 2006
Case study comparisons of computational fluid dynamics (CFD) modeling versus tracer testing for determining clearwell residence times in drinking water treatment Available to Purchase
Publisher: Emerald Publishing
Online ISSN: 1496-256X
Print ISSN: 1496-2551
Journal of Environmental Engineering and Science (2006) 5 (6): 529–536.
Citation
Templeton MR, Hofmann R, Andrews RC (2006), "Case study comparisons of computational fluid dynamics (CFD) modeling versus tracer testing for determining clearwell residence times in drinking water treatment". Journal of Environmental Engineering and Science, Vol. 5 No. 6 pp. 529–536, doi: https://doi.org/10.1139/s06-007
Download citation file:
Suggested Reading
Non-enzymatic degradation of chlorofluorocarbon 113 using cyanocobalamin under anaerobic conditions
Journal of Environmental Engineering and Science (July,2004)
Impact of organic waste amendments on soil hydraulic properties and on water partitioning
Journal of Environmental Engineering and Science (May,2006)
Fouling assessment in a municipal water reclamation reverse osmosis system as related to concentration factor
Journal of Environmental Engineering and Science (January,2004)
Particle penetration through rectangular-shaped cracks
Journal of Environmental Engineering and Science (August,2006)
Ozone treatment for the degradation of resin and unsaturated fatty acids at low temperatures
Journal of Environmental Engineering and Science (August,2006)
Related Chapters
Ice
Innovate to Survive: Engineers for a One Planet Future
Ice
Innovate to Survive: Engineers for a One Planet Future
Innovate to Survive: Engineers for a One Planet Future
Innovate to Survive: Engineers for a One Planet Future
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.