The prime objective of this study is to look at the bearing capacity of a thin-walled spread foundation system in cohesionless soils. In this regard, laboratory-footing load tests were on the aforementioned footing in loose and dense sands. The Johor Bahru sand used is this study was dried and characterised in the laboratory. To investigate the beneficial effect of the thin walls on the bearing capacity of the footing, laboratory footing load tests were also conducted on a simple surface footing and the results were compared. For verification purposes, the experimentally obtained bearing capacities of thin-walled foundation were checked against finite-element analyses. The experimental findings show an enhancement of the bearing capacity by a factor of almost 2 when the thin-walled footing is used instead of a simple footing. The bearing capacities of the thin-walled footing in loose and dense sands predicted using finite-element analyses were different to the laboratory observations by 10%.
Article navigation
December 2015
Editors
Research Article|
October 05 2015
Bearing capacity of precast thin-walled foundation in sand
Ehsan Momeni, PhD;
Ehsan Momeni, PhD
Researcher
Department of Geotechnics and Transportation, Universiti Teknologi Malaysia, Skudai, Malaysia
Search for other works by this author on:
Ramli Nazir, PhD;
Ramli Nazir, PhD
Professor
Department of Geotechnics and Transportation, Universiti Teknologi Malaysia, Skudai, Malaysia
Search for other works by this author on:
Danial Jahed Armaghani, PhD;
Danial Jahed Armaghani, PhD
Researcher
Young Researchers and Elite Club, Qaemshahr Branch, Islamic Azad University, Qaemshahr, Iran
Search for other works by this author on:
Houman Sohaie, PhD candidate
Houman Sohaie, PhD candidate
Researcher
Department of Geotechnics and Transportation, Universiti Teknologi Malaysia, Skudai, Malaysia
Search for other works by this author on:
Publisher: Emerald Publishing
Received:
November 25 2014
Accepted:
July 15 2015
Online ISSN: 1751-8563
Print ISSN: 1353-2618
ICE Publishing: All rights reserved
2015
Proceedings of the Institution of Civil Engineers - Geotechnical Engineering (2015) 168 (6): 539–550.
Article history
Received:
November 25 2014
Accepted:
July 15 2015
Citation
Momeni E, Nazir R, Armaghani DJ, Sohaie H (2015), "Bearing capacity of precast thin-walled foundation in sand". Proceedings of the Institution of Civil Engineers - Geotechnical Engineering, Vol. 168 No. 6 pp. 539–550, doi: https://doi.org/10.1680/jgeen.14.00177
Download citation file:
New and popular articles
Suggested Reading
Generalised dynamical systems soil deformation model
Geotechnical Research (March,2014)
Experimental evaluation of ultimate bearing capacity of the cutting edge of an open caisson
International Journal of Physical Modelling in Geotechnics (April,2019)
Swell and compressibility of fly ash−clay blends in lumps and powders: effect of 4% lime
Proceedings of the Institution of Civil Engineers - Ground Improvement (August,2019)
Improvement of chalk solution feature infill by rapid impact compaction
Proceedings of the Institution of Civil Engineers - Ground Improvement (January,2022)
Predictions of footing and pressuremeter response in sand using a hardening soil model
Proceedings of the Institution of Civil Engineers - Geotechnical Engineering (June,2017)
Related Chapters
Tower crane bases
Temporary Works: Principles of Design and Construction
Case study IV: Reinforced concrete foundation
Empirical Design in Structural Engineering
INFORMAL DISCUSSION: Session 1 Formation and Engineering Geology of Stiff Clays
Stiff Sedimentary Clays: Genesis and Engineering Behaviour: Géotechnique Symposium in Print 2007
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.