Keywords: Fire test
Close
Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Journal Articles
Journal of Structural Fire Engineering (2022) 13 (2): 205–223.
Published: 23 November 2021
... Achieving the optimum design for the internal door stiffeners where the hat omega stiffener gives minimum door deformation compared to the other stiffeners was considered the practical implication. The work included two experimental fire door tests according to the standard fire test (ANSI/UL 10C – Positive...
Journal Articles
Journal Articles
Journal Articles
Journal of Structural Fire Engineering (2020) 11 (1): 22–32.
Published: 16 August 2019
... The findings based on fire tests contribute to a better understanding of the intumescent coating performance on connection components of tension rod systems. This subject has not been extensively studied yet. The performance of intumescent coatings on steel tension members with circular solid section has...
Journal Articles
Journal of Structural Fire Engineering (2018) 9 (4): 319–341.
Published: 19 April 2018
... 06 11 2017 12 12 2017 28 12 2017 © Emerald Publishing Limited 2018 Emerald Publishing Limited Licensed re-use rights only Fire test Load-bearing capacity Design methods Light aggregate concrete Walls Light weight concrete based on expanded clay aggregate differ...
Journal Articles
Journal of Structural Fire Engineering (2017) 8 (3): 324–336.
Published: 07 July 2017
..., it compares theoretical calculation and assessment according to the structural codes with data derived from a standard fire test and from a thorough examination of the comprehensive test documentation available on fire exposed hollow-core slabs. Findings Mechanisms for loss of load-bearing capacity...
Journal Articles
Journal of Structural Fire Engineering (2016) 7 (1): 19–29.
Published: 14 March 2016
...David J. Proe Purpose This paper aims to facilitate verification of computer modelling techniques for complex structures exposed to fire and to test the effect of some steel beams being left unprotected. Design/methodology/approach This paper describes a fire test conducted on a large-scale...
Journal Articles
Journal of Structural Fire Engineering (2015) 6 (1): 21–28.
Published: 01 March 2015
...Tomáš Jána; František Wald The paper is focused to the temperature distribution in the reverse channel connections to concrete filled tubular column during two fire tests on an experimental building in Veselí nad Lužnicí. Temperatures of connections without fire protection as well as fire protected...
Journal Articles
Journal of Structural Fire Engineering (2014) 5 (4): 291–330.
Published: 01 December 2014
...Anthony Ariyanayagam; Mahen Mahendran This paper presents the details of full scale fire tests of LSF wall panels conducted using realistic fire time-temperature curves. Tests included eight LSF wall specimens of various configurations exposed to both parametric design and natural fire curves...
Journal Articles
Journal of Structural Fire Engineering (2014) 5 (2): 175–188.
Published: 01 June 2014
...Gisèle Bihina; Bin Zhao; Abdelhamid Bouchaïr The main results from a numerical investigation on a composite floor made of cellular beams at elevated temperatures are presented. From a full-scale natural fire test, a 3D finite element model has been developed under ANSYS code to simulate the thermo...
Journal Articles
Journal of Structural Fire Engineering (2013) 4 (2): 71–86.
Published: 01 June 2013
... in fire condition. Recently, further three fire tests were carried out on concrete slabs reinforced with GFRP bars bent at the ends. The anchoring of the FRP bars in the zone of slab not directly exposed to fire at the end of the members revealed essential to ensures slab resistance, once in the fire...
Journal Articles
Journal of Structural Fire Engineering (2013) 4 (1): 1–8.
Published: 01 March 2013
... in a European-collaborative project which concerns the behaviour and robustness in fire of practical connections to composite columns. This includes two natural fire tests in a full-scale composite structure in Veselí, the Czech Republic. The Sheffield team was responsible for predicting the structural...