Gated conduits involve high-velocity air–water flow. When studies on gated conduits are examined, it is determined that the air-demand ratio changes according to the hydraulic and geometric parameters. However, no study has investigated the effect of the cross-sectional geometry of high-head conduits with a sluice gate on the air-demand ratio. In this study, the effect of conduit cross-sectional geometry on the air-demand ratio is examined. Results indicate that a conduit's cross-sectional geometry has an important effect on the air-demand ratio, especially at 10% and 15% gate opening rates. It is seen that the effect of the conduit geometry on the air-demand ratio decreases at 20%, and for greater gate opening rates. Moreover, a formula for estimated the air-demand ratio is presented, relating the air-demand ratio to the gate opening rate, Froude number, hydraulic radius and conduit length.
Article navigation
August 2024
Research Article|
June 09 2023
Investigation of the geometry effect on air-demand ratio in conduits with a sluice gate
Alp Bugra Aydin;
Alp Bugra Aydin
Assistant Professor, Department of Civil Engineering, Firat University, Elazig, Turkey
Search for other works by this author on:
Ahmet Baylar
;
Ahmet Baylar
Professor, Department of Civil Engineering, Eskisehir Technical University, Eskisehir, Turkey (corresponding author: abaylar@eskisehir.edu.tr)
Search for other works by this author on:
Fahri Ozkan;
Fahri Ozkan
Professor, Department of Civil Engineering, Firat University, Elazig, Turkey
Search for other works by this author on:
Muhammed Cihat Tuna
;
Muhammed Cihat Tuna
Associate Professor, Department of Civil Engineering, Firat University, Elazig, Turkey
Search for other works by this author on:
Mualla Ozturk
Mualla Ozturk
Professor, Department of Civil Engineering, Munzur University, Tunceli, Turkey
Search for other works by this author on:
Publisher: Emerald Publishing
Received:
May 24 2022
Accepted:
April 28 2023
Online ISSN: 1751-7729
Print ISSN: 1741-7589
Emerald Publishing Limited: All rights reserved
2023
Proceedings of the Institution of Civil Engineers - Water Management (2024) 177 (4): 201–210.
Article history
Received:
May 24 2022
Accepted:
April 28 2023
Citation
Aydin AB, Baylar A, Ozkan F, Tuna MC, Ozturk M (2024), "Investigation of the geometry effect on air-demand ratio in conduits with a sluice gate". Proceedings of the Institution of Civil Engineers - Water Management, Vol. 177 No. 4 pp. 201–210, doi: https://doi.org/10.1680/jwama.22.00048
Download citation file:
New and popular articles
Suggested Reading
Precision low flow pulseless fluid delivery
Pigment & Resin Technology (September,2006)
Derivation of a 130 year run-off record from sluice records for the Loch Leven catchment, south-east Scotland
Proceedings of the Institution of Civil Engineers - Water Maritime and Energy (June,1992)
Spread of a surface plume in unsteady and steady flows
Proceedings of the Institution of Civil Engineers - Water Maritime and Energy (June,1992)
Non-steady flow in the variable-head permeability test
Geotechnique (November,2005)
Darcy's law and the differential equation of motion
Geotechnique (August,2009)
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.